Hi Arpad,

If I understand the question, it's "What's the reference point for placing the 
eye mask template?" ? [that mask can be Tx or Rx sides, depending on the 
standard chosen]

My view is:
There is no absolute reference given the nature of the links.
The common practice is to centre the mask inside the output eye, but this is 
completely tester determined [we're talking compliance testing here]. Given 
that the horizontal and vertical edge points are defined, the absolute timing 
reference doesn't matter - that's the whole point of the link....timing/data 
extraction.

Regards,
Richard

-----Original Message-----
From: ibis-macro-bounce@xxxxxxxxxxxxx [mailto:ibis-macro-bounce@xxxxxxxxxxxxx] 
On Behalf Of Muranyi, Arpad
Sent: Tuesday, December 08, 2009 10:43 AM
To: IBIS-ATM
Subject: [ibis-macro] Re: Eye mask question

Sorry for my poor problem statement...

I mean the output of Rx (as it comes back from
Rx GetWave), used together with the clock ticks
from Rx GetWave to formulate the eye.

Arpad
================================================

-----Original Message-----
From: Todd Westerhoff [mailto:twesterh@xxxxxxxxxx] 
Sent: Tuesday, December 08, 2009 12:40 PM
To: Muranyi, Arpad
Cc: IBIS-ATM
Subject: Re: [ibis-macro] Eye mask question

Arpad,

Not meaning to be enigmatic here, but what signal(s) are you thinking 
get used to generate the eye diagram, and how?

Todd.

Todd Westerhoff
VP, Software Products
SiSoft
6 Clock Tower Place, Suite 250
Maynard, MA 01754
(978) 461-0449 x24
twesterh@xxxxxxxxxx
www.sisoft.com



Muranyi, Arpad wrote:
> Hello IBIS-AMI experts,
>
> This is a question regarding the analysis/evaluation
> of the results we get back from an AMI simulation.
>
> How does the user decide whether the eye is good or bad?
>
> Naturally we have this thing called eye mask (template)
> which we would all be able to drop into the eye without
> touching any of the waveforms.  But where are we trying
> to position it?  Anywhere it fits the best way?  Or is
> it supposed to be positioned at a certain location?
>
> Thanks for any feedback in advance,
>
> Arpad
> =========================================================
> ---------------------------------------------------------------------
> IBIS Macro website  :  http://www.eda.org/pub/ibis/macromodel_wip/
> IBIS Macro reflector:  //www.freelists.org/list/ibis-macro
> To unsubscribe send an email:
>   To: ibis-macro-request@xxxxxxxxxxxxx
>   Subject: unsubscribe
>
>   
---------------------------------------------------------------------
IBIS Macro website  :  http://www.eda.org/pub/ibis/macromodel_wip/
IBIS Macro reflector:  //www.freelists.org/list/ibis-macro
To unsubscribe send an email:
  To: ibis-macro-request@xxxxxxxxxxxxx
  Subject: unsubscribe

---------------------------------------------------------------------
IBIS Macro website  :  http://www.eda.org/pub/ibis/macromodel_wip/
IBIS Macro reflector:  //www.freelists.org/list/ibis-macro
To unsubscribe send an email:
  To: ibis-macro-request@xxxxxxxxxxxxx
  Subject: unsubscribe

Other related posts: