[aravis] Re: Aravissrc: Multi-camera Ethernet Network Performance

  • From: Emmanuel Pacaud <emmanuel.pacaud@xxxxxxxxxxxxx>
  • To: aravis@xxxxxxxxxxxxx
  • Date: Thu, 21 Dec 2017 10:31:03 +0100

Hi Ian,

Le mar. 19 déc. 2017 à 19:27, Ian McCoy <immccoy78@xxxxxxxxx> a écrit :

In the end, I switched the frame size to 6000 and increased the delay. The camera delays were offset about 3000. Camera 1 was set to 3000 and Camera 2 set to 6000. This resolved the problem and I was able to stream both cameras simultaneously. This was tested on the both switches successfully: tp-link and netgear pro safe (GS105). This seems counterintuitive to everything I have read about setting the packet size to largest possible setting your is network cable of, but apparently not in this case!

Hope this helps someone and I appreciate the help and comments you sent.

Thanks for the follow up.

In the end, are you using aravis, or did you switch to flycap ?

                Emmanuel.