[TechAssist] Re: Zenith SG2589W No power up

  • From: "Shoreline Electronics" <jstielau@xxxxxxxx>
  • To: <techassist@xxxxxxxxxxxxx>
  • Date: Mon, 8 Oct 2001 12:49:01 -0400

Mike,

 Be safe & change C3407 100uf/50v Between Heatsink & Main Filter  ...even if
it checks good & even though you have B+ on the HOT

Also check : Rx3242  in flyback circuit  & Cr3411 18v To220 Rectifier On
Smps Heat Sink

Jeff Stielau
Shoreline Electronics Repair
125 Beechtree Lane
Westbrook,CT 06498
860-399-1861 Voice
860-664-3535 Fax
jstielau@xxxxxxxx

----- Original Message -----
From: "Mike Barnett" <passthecash@xxxxxxxxxx>
To: <techassist@xxxxxxxxxxxxx>
Sent: Monday, October 08, 2001 9:18 AM
Subject: [TechAssist] Zenith SG2589W No power up


>
> Zenith Model SG2589W  Module# 9-958
> This unit wont power up, standby 5v is present and have 136 at collector
of
> HOT, vcc at vertical is ok. Checked all caps in power primary and high
> voltage curcuit all are ok. checked resistors near and around fly.
> Any idea's?
> Thanks
>
>
>
> Get It Fixed At
> Rochester Electronics
> 630 West Ridge Rd.
> Rochester, NY 14615
> 716.663.6870
> www.RochesterElectronicsRepair.com
>
>
>
>
>
> _______________________________________________________
> Send a cool gift with your E-Card
> http://www.bluemountain.com/giftcenter/
>
>
> Help make your TechAssist online repair tips
> database better!  Submit your fixes here:
> http://www.circuitwork.com/techassist/tip/#tips
> To unsubscribe write to:
> techassist-request@xxxxxxxxxxxxx
> with  unsubscribe  in the subject line.
>

Help make your TechAssist online repair tips 
database better!  Submit your fixes here: 
http://www.circuitwork.com/techassist/tip/#tips
To unsubscribe write to:
techassist-request@xxxxxxxxxxxxx 
with  unsubscribe  in the subject line.

Other related posts: