On mantis someone integrated Cacti into Racktables. Assuming all your PDUs are SNMP capable this should be what you need. Basically, leave the PUE reporting to Cacti. Bryan On Sun, 2010-04-18 at 12:40 -0400, jorge severino wrote: > Yes, electrical use is very important for provisioning and VMWARE > infraestructure is the same. > > I will collaborate in expand for new features. > > Atte > JSD > > > 2010/4/17 Michael Camino <mikeyc@xxxxxxxxxxxxxx> > > Hello All, > I have been using the rack tables software for almost a > year now to manage a data center and I am looking to extend > the software features in a couple ways. I have read the > archive and have not found the exact answers I am looking for. > I read a lot of previous posts which talk about changes people > may have made but i do not see any of their code added to any > of the development branches or any specific code changes being > posted to the list. If i am incorrect please feel free to > correct me and point me in the right direction. > > The first feature I am looking to add is the ability to handle > patch panels and be able to see through to the other end of > it. Right now our users select an available switch port on our > switches and we cable up between their rack location and the > patch panel and switch ports. It would be great if they could > select a patch panel port located in their rack and then > select the end port on a switch. Then my job would only be to > put the cables where they selected. I know about mounting a > patch panel in 2 racks, and that gets me 1/2 way there. What > it doesn't let them do is have 2 devices , one server and one > switch port, connect to that same patch panel port. It also > doesn't allow them to see the "end port". > > The second feature is a reporting one.In each of our racks we > have two or four PDU's. For each of our server objects we > have 2 custom fields one for BTU and one for Watts. I would > like some way to build reports based on PDU electrical usage. > So if we have 5 devices each pulling 500 watts from PDU-A and > two devices pulling 700 watts from PDU-B i am looking for some > way to create or view a report which says the amount of > theoretical wattage being used on each pdu compared to the > input wattage, then per rack, and then in the whole data > center. I have the pdu's setup with 8 AC-OUT ports and 1 AC-IN > Port but no way of combining connected devices onto the same > pdu via the mysql database. > > The third feature I am looking for is some thoughts on VMWARE > and Rack tables. Obvious virtual infrastructure is something > which might be out of the purpose of a software design for > physical reporting. I understand that. What i am looking for > is some suggestions on how other members might be doing this. > > > > > >