[ibis-macro] Re: What part of Legacy IBIS is used by IBIS-AMI

  • From: "Muranyi, Arpad" <Arpad_Muranyi@xxxxxxxxxx>
  • To: IBIS-ATM <ibis-macro@xxxxxxxxxxxxx>
  • Date: Wed, 11 Jul 2012 03:44:03 +0000

That is correct.

Arpad
================

From: ibis-macro-bounce@xxxxxxxxxxxxx [mailto:ibis-macro-bounce@xxxxxxxxxxxxx] 
On Behalf Of Mirmak, Michael
Sent: Tuesday, July 10, 2012 6:07 PM
To: Walter Katz
Cc: IBIS-ATM
Subject: [ibis-macro] Re: What part of Legacy IBIS is used by IBIS-AMI

Walter,

Thank you!  So, someone using IBIS-AMI models with valid traditional data in a 
workflow should expect changes in the IBIS TX C_comp or V-t (or [Ramp]) data to 
have an impact on the results provided by the receiver in an IBIS-AMI-based 
flow, assuming nothing else changes?


-          MM

From: Walter Katz [mailto:wkatz@xxxxxxxxxx]<mailto:[mailto:wkatz@xxxxxxxxxx]>
Sent: Tuesday, July 10, 2012 12:20 PM
To: Mirmak, Michael
Cc: IBIS-ATM
Subject: What part of Legacy IBIS is used by IBIS-AMI

MM,

The Legacy part of an IBIS model is used to generate the Impulse Response of 
the channel.

One method of generating the impulse response is to do a step response, and 
take the derivative of the waveform at the Rx input.

A simulator uses a combination of the Tx [Voltage Range], C_Comp, IV, VT and 
Ramp data, and the Rx C_Comp and IV data. Of course, [External Model] can also 
be used by a simulator.

The following required Tx IBIS fields are not used in the AMI flow:
Vmeas
The following required Rx IBIS fields are not used in the AMI flow:
Vinl
Vinh

Walter


Walter Katz
wkatz@xxxxxxxxxx<mailto:wkatz@xxxxxxxxxx>
Phone 303.449-2308
Mobile 303.335-6156

Other related posts: