[TechAssist] Re: Toshiba CF3266A TAC9170 remote funtions fail after 30min of operation

  • From: Kevin <kevintv@xxxxxxx>
  • To: techassist@xxxxxxxxxxxxx
  • Date: Sat, 20 Mar 2004 15:23:52 -0800

Sounds like a bad connection on a voltage regulator.  I had one that
acted like it was a bad uP, but turned out to be just bad connections
that I missed because of the plastic housing around the circuit board.
HTH

Kevin Wilks
Kevin's TV & Video Repair
Penticton BC Canada
kevintv@xxxxxxx 
 

-----Original Message-----
From: techassist-bounce@xxxxxxxxxxxxx
[mailto:techassist-bounce@xxxxxxxxxxxxx] On Behalf Of Peter oliver
Sent: Saturday, March 20, 2004 1:57 PM
To: techassist@xxxxxxxxxxxxx
Subject: [TechAssist] Toshiba CF3266A TAC9170 remote funtions fail after
30 min of operation

Toshiba CF3266A
TAC9170
MFD Oct 1991
(set is a 32" but looks much bigger due to the forward facing side  
speakers)

            This set came in about the time I was leaving the shop
today. 
The complaint given is that any remote control will cease to operate the
tv 
after about 30 min of operation, apparently front panel functions remain

unaffected (didn't get a chance to verify yet). Does this discription
jog 
any memorys on where to start, otherwise it is probabbly the solder
shotgun 
approch, change the high failure caps, etc......

Peter Oliver
Tucson Radio TV

_________________________________________________________________
Find a broadband plan that fits. Great local deals on high-speed
Internet 
access. http://click.atdmt.com/AVE/go/onm00200360ave/direct/01/


------------------------------------------------------------------------
-----
Lost Password:
http://www.tech-assist.org  and select "Login Problems?".
Email Archives:
//www.freelists.org/archives/techassist/


-----------------------------------------------------------------------------
Lost Password:
http://www.tech-assist.org  and select "Login Problems?".
Email Archives:
//www.freelists.org/archives/techassist/

Other related posts:

  • » [TechAssist] Re: Toshiba CF3266A TAC9170 remote funtions fail after 30min of operation