David, check for open r424 causes q402 to run hot and shorten life. Also check for intermitting high resistance joint on c 406 in the horz.tank circuit. also suspect c423 (.016uf c425 .39 uf c426. cr411 cr412 c431,c432,c433, when HOT is found shorted. These are just a few things that might help. >From: "David Lessard" <mr_fixit@xxxxxxxxxxxx> >Reply-To: techassist@xxxxxxxxxxxxx >To: <techassist@xxxxxxxxxxxxx> >Subject: [TechAssist] [TechAssit] RCA - 27" TV - PMR623ER - CTC130A - Dead >- Shorted HOT >Date: Mon, 3 Oct 2005 21:21:46 -0400 > >This TV has a shorted HOT (C1308K), main fuse is blown. Are there any >common problems besides a bad flyback which could cause this? >Thanks in advance, >David Lessard >Alexandria, Ontario, Canada >mr_fixit@xxxxxxxxxxxx >----------------------------------------------------------------------------- >This Email List is accessible to the general public through search engines. >Remove: http://www.tech-assist.org/remove.htm >Set Vacation >mailto:ecartis@xxxxxxxxxxxxx?subject=set%20techassist%20vacation >Lost Password: http://www.tech-assist.org and select "Login Problems?". >Email Archives: //www.freelists.org/archives/techassist/ _________________________________________________________________ FREE pop-up blocking with the new MSN Toolbar ? get it now! http://toolbar.msn.click-url.com/go/onm00200415ave/direct/01/ ----------------------------------------------------------------------------- This Email List is accessible to the general public through search engines. Remove: http://www.tech-assist.org/remove.htm Set Vacation mailto:ecartis@xxxxxxxxxxxxx?subject=set%20techassist%20vacation Lost Password: http://www.tech-assist.org and select "Login Problems?". Email Archives: //www.freelists.org/archives/techassist/