Set started dead replaced Q601, Q602 R606 . Set played for a few minutes and shut down . Now set shutsdown immeadiately. #.15 a fuses are good.Found sony flow chart that seems toisolate problem to g or a boards, Unloaded power supply voltages are nominal except for the --135v line which is about --175. Q662/660 are in protect mode . I suspect t602 has anyone seen this.Thanks Vince of vinces tv Mt. holly N.j. Vmiraglia@xxxxxxx , ----------------------------------------------------------------------------- This Email List is Public. Remove: http://www.tech-assist.org/remove.htm Lost Password: http://www.tech-assist.org and select "Login Problems?". Email Archives: //www.freelists.org/archives/techassist/