Check Q4702-E for 12V LOC 14BB If low ck CR4118-K for abt 15V CR4118 @ Xmfr-3 often fails Q4705 will work only if the flyback is running. It is powered by th 26V line @ Fly-8 ON/OFF flow is U3101-38 Q4306 Q4304 Q4301 Q4305-E which supplies 9V to horiz osc - turns high voltage ON Tomlee wrote: > Hello Perry. > I am sorry that I tell something wrong. Actually the tv has good B+ 160v. > But When I push power button. I see voltage at pin 38 of Microcontrol goes > up a bit about one volt then goes down. so q4705 never turn on and q4702 > never turn on. So > it miss source #3 12v. and some sources come from q4703.I do not know it > is protected or power supply fails by itself. > thank for help. Dang TVCR > ----- Original Message ----- > From: "Electric Medic" <info@xxxxxxxxxxxxxxxxx> > To: <techassist@xxxxxxxxxxxxx> > Sent: Tuesday, January 22, 2002 9:53 PM > Subject: [TechAssist] Re: Proscan ctc169bj5 dead > > > > > Check these things: > > Change C4108 which causes high bias on Q4101 (200165) > > and its failure. Also replace U4101(200419). Do not sub Chopper or IC. > Done > > 100's of these, if you do not replace IC and C4108, the set will recall in > > most cases. Also change C4118 and C4102 The main thing to check is > > your B+ in stand by which all of the above caps, if defective, will go as > > high as 200 volts (it's supposed to be approximately 140 volts) > > > > Perry Bower > > Electric Medic > > "It's Cheaper to Keep Her" > > 3850 Washington Road Suite 5b > > Martinez, Georgia 30907 > > Phone: 706-8MEDIC4 (863-3424) > > Phone: 706-863-3474 > > Fax: 706-863-2316 > > Website: www.electricmedic.com > > mailto:info@xxxxxxxxxxxxxxxxx > > "WE REPAIR WITH CARE" > > More Info: www.augusta-ga.bbb.org/report.html?compid=6001278&national=y > > > > Factory Trained Authorized Service Center For: Fisher, GE, KEC/KTV, > Konka, > > Mitsubishi, Panasonic, Philips Magnavox, Pioneer, ProSCAN, RCA, Samsung, > > Sanyo, Sharp, SONY, Technics, Zenith > > > > Provide Extended care for: AON, Circuit City, GE Contracts, Glass Agency, > > Philips Contracts, NEW, Rex > > > > > > -----Original Message----- > > From: techassist-bounce@xxxxxxxxxxxxx > > [mailto:techassist-bounce@xxxxxxxxxxxxx]On Behalf Of Tomlee > > Sent: Tuesday, January 22, 2002 11:20 PM > > To: techassist@xxxxxxxxxxxxx > > Subject: [TechAssist] Proscan ctc169bj5 dead > > > > > > > > Hello techs. > > I am working with proscan CTC169BJ5. it is dead .Q4101 is not working. > > suspect ic 4101 fails. Is there any tips for this problem.TIA.I am not > > familiar with this brand TV. > > Dang TVCR > > > > ------------------------------------------ > > Make your TechAssist database better! > > Submit Repair Tips here: http://www.tech-assist.org/secure/tip/ > > ------------------------------------------ > > To UNSUBSCRIBE your email address, click here: > > mailto:techassist-request@xxxxxxxxxxxxx?subject=unsubscribe > > Or send a BLANK email with unsubscribe in the > > SUBJECT field to the address above. > > > > ------------------------------------------ > > Make your TechAssist database better! > > Submit Repair Tips here: http://www.tech-assist.org/secure/tip/ > > ------------------------------------------ > > To UNSUBSCRIBE your email address, click here: > > mailto:techassist-request@xxxxxxxxxxxxx?subject=unsubscribe > > Or send a BLANK email with unsubscribe in the > > SUBJECT field to the address above. > > > > ------------------------------------------ > Make your TechAssist database better! > Submit Repair Tips here: http://www.tech-assist.org/secure/tip/ > ------------------------------------------ > To UNSUBSCRIBE your email address, click here: > mailto:techassist-request@xxxxxxxxxxxxx?subject=unsubscribe > Or send a BLANK email with unsubscribe in the > SUBJECT field to the address above. ------------------------------------------ Make your TechAssist database better! Submit Repair Tips here: http://www.tech-assist.org/secure/tip/ ------------------------------------------ To UNSUBSCRIBE your email address, click here: mailto:techassist-request@xxxxxxxxxxxxx?subject=unsubscribe Or send a BLANK email with unsubscribe in the SUBJECT field to the address above.