That's the same information I have from Philips except for OB7 which is 000 and the FMR remote has no settings in the instructions to set OB7 to anything other than 000. Also note the new set which works has option bytes of 000 215 129 162 164 088 000, the FMR will not set OB2 to 215, OB5 to 164 or OB6 to 088. Jim Myers Telrad Electronic Services Co. Fort Wayne, IN 46815 jr.myers@xxxxxxxxxxx 260-432-4486 Fax and Voice Fax is always on ----- Original Message ----- From: "Phillip R. Hull" <phil245@xxxxxxxxxxxxx> To: <techassist@xxxxxxxxxxxxx> Sent: Thursday, March 28, 2002 4:16 PM Subject: [TechAssist] Re: Magnavox MS3650C129 & MS3250C121, M8 chassis option bytes lets try it again MS3250C121 00 87 129 162 196 152 64 MS3650c129 00 87 129 162 196 24 64 Phillip R Hull phil245@xxxxxxxxxxxxx ----- Original Message ----- From: "Phillip R. Hull" <phil245@xxxxxxxxxxxxx> To: <techassist@xxxxxxxxxxxxx> Sent: Thursday, March 28, 2002 4:10 PM Subject: [TechAssist] Re: Magnavox MS3650C129 & MS3250C121, M8 chassis option bytes > > Its in the Force 32 program if you loaded the manuals, > > MS3250C121 MS3650C129 > > OB1 00 OB1 > 00 > OB2 87 OB2 > 87 > OB3 129 OB3 > 129 > OB4 162 OB4 162 > OB5 196 OB5 196 > OB6 152 OB6 24 > OB7 64 OB7 64 > > Phillip R Hull > phil245@xxxxxxxxxxxxx > ----- Original Message ----- > From: "Jim Myers" <jr.myers@xxxxxxxxxxx> > To: <techassist@xxxxxxxxxxxxx> > Sent: Thursday, March 28, 2002 3:09 PM > Subject: [TechAssist] Magnavox MS3650C129 & MS3250C121, M8 chassis option > bytes > > > > > > Hi all, I have two Magnavox sets, M8 chassis with same problem of the A/V > > input not working. I'm sure the problem is incorrect data in the option > > bytes, I have the Factory Mode Remote and the instructions and have the > > "correct" option byte data from Philips entered and saved. I also have a > > third set, new just out of the box with no problems, same model and > chassis. > > Checking the option bytes in the working new set I find the data is not > only > > different but also not listed in the FMR instructions, no way to enter the > > data that is there. > > Details, Model MS3650C129 option bytes in the set with the A/V problem is > > 000 087 129 162 196 024 000 and is correct per Philips. > > New set same model, A/V input works 000 215 129 162 164 088 000. The FMR > > remote is not capable of entering this data. Philips does not have the > > answer, does anyone here have it? This set does not have the SAM, CAM etc > > the only was to access service mode is with the FMR. > > Thanks > > Jim Myers > > Telrad Electronic Services Co. > > Fort Wayne, IN 46815 > > jr.myers@xxxxxxxxxxx > > 260-432-4486 Fax and Voice > > Fax is always on > > > > ------------------------------------------ > > Make your TechAssist database better! > > Submit Repair Tips here: http://www.tech-assist.org/secure/tip/ > > ------------------------------------------ > > To UNSUBSCRIBE your email address, click here: > > mailto:techassist-request@xxxxxxxxxxxxx?subject=unsubscribe > > Or send a BLANK email with unsubscribe in the > > SUBJECT field to the address above. > > > > > > ------------------------------------------ > Make your TechAssist database better! > Submit Repair Tips here: http://www.tech-assist.org/secure/tip/ > ------------------------------------------ > To UNSUBSCRIBE your email address, click here: > mailto:techassist-request@xxxxxxxxxxxxx?subject=unsubscribe > Or send a BLANK email with unsubscribe in the > SUBJECT field to the address above. > > ------------------------------------------ Make your TechAssist database better! Submit Repair Tips here: http://www.tech-assist.org/secure/tip/ ------------------------------------------ To UNSUBSCRIBE your email address, click here: mailto:techassist-request@xxxxxxxxxxxxx?subject=unsubscribe Or send a BLANK email with unsubscribe in the SUBJECT field to the address above. ------------------------------------------ Make your TechAssist database better! Submit Repair Tips here: http://www.tech-assist.org/secure/tip/ ------------------------------------------ To UNSUBSCRIBE your email address, click here: mailto:techassist-request@xxxxxxxxxxxxx?subject=unsubscribe Or send a BLANK email with unsubscribe in the SUBJECT field to the address above.