[TechAssist] Re: Hitachi model 43FWX20B sync problem.FIX

  • From: Jim Myers <jr.myers@xxxxxxxxxxx>
  • To: techassist@xxxxxxxxxxxxx
  • Date: Wed, 20 Apr 2005 08:57:17 -0500

IC910, 9 volt regulator on the power supply board was putting out 
between 6 and 7 volts when cold. This was a newly rebuilt PTS board so I 
didn't look there thinking it would be all ok. NOT! This supplies 9V to 
the rain forest IC.


********************************
Since 1972                     *
Jim Myers                      *
Telrad Electronics             *
Fort Wayne Indiana             *
********************************


Jim Myers wrote:
> The sync on This set will not lock for about three to five minutes when 
> first turned on then it locks but still may loose sync on a weak signal. 
>   Problem is same using external A/V input so it's not a tuner problem. 
> I have replaced the rain forest IC, no help, also since everything I 
> checked pointed to the CS00641A module I sent it to PTS for repair but 
> still have the same problem. Any and all suggestions will be welcome.
> 
> Thanks,
> PS, Yes, I tried circuit cooler, no help.
> ********************************
> Since 1972                     *
> Jim Myers                      *
> Telrad Electronics             *
> Fort Wayne Indiana             *
> ********************************
> -----------------------------------------------------------------------------
> This Email List is Public. Remove: http://www.tech-assist.org/remove.htm
> Lost Password: http://www.tech-assist.org  and select "Login Problems?".
> Email Archives: //www.freelists.org/archives/techassist/
> 
-----------------------------------------------------------------------------
This Email List is Public. Remove: http://www.tech-assist.org/remove.htm
Lost Password: http://www.tech-assist.org  and select "Login Problems?".
Appliance Repair List: http://www.tech-assist.org/secure/tip/chatjoin.htm#app
Email Archives: //www.freelists.org/archives/techassist/

Other related posts: