Jim, Don't see a 26 with that model number, but have a CT2553. Vertical caps C601, 220ufd@50vdc. C602, 100ufd@50vdc. C605, 1000ufd@16vdc. Uses an LA7830 vert.out Check for bad solder joints. Clean the three position tuner band switch for the memory issue on the antenna jack assembly. And send me a few of these customers. Nice money. Dominic DiLeo Atlantic TV Freeport, Maine ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ In a message dated 7/2/2005 11:27:51 AM Eastern Daylight Time, jr.myers@xxxxxxxxxxx writes: Old Hitachi console Model CT-2653 customer approved est of 250.00. 3 Problems: 1. Vertical deflection problem, top of pix is down 3 or 4 inches and stretched out on bottom. 2. A black bar appears when channel is changed. the bar is about 4 or 5 inches wide comes down from top almost to bottom of picture and is centered on the right side. 3. Channel memory add/erase does not work. Set is in home and customer would like it repaired on site if possible. If no tips then maybe a schematic so I can do it the hard way? Thanks, ******************************** Since 1972 * Jim Myers * Telrad Electronics * Fort Wayne Indiana * ******************************** ----------------------------------------------------------------------------- This Email List is Public. Remove: http://www.tech-assist.org/remove.htm Set Vacation mailto:ecartis@xxxxxxxxxxxxx?subject=set%20techassist%20vacation Lost Password: http://www.tech-assist.org and select "Login Problems?". Email Archives: //www.freelists.org/archives/techassist/