Phil, This is a very common problem. Bob Waterman, CET® #RI-28 Master Technician License #9109 Service Manager / Parts Manager Gemini Computer, TV, & Security Alarms (508)695-7302 (508)695-7769 FAX geminitv@xxxxxxxxxxx ----- Original Message ----- From: "Phil Bader" <tjanphyl@xxxxxxxxxxxxxxx> To: <techassist@xxxxxxxxxxxxx> Sent: Thursday, March 31, 2005 10:53 AM Subject: [TechAssist] Hitachi 50UX8B in shut down. D912 protect diode flashing, FIX > Submitted by local shop. > Powered on this set, smelled something like a HV arc. > Pico fuse E994 open > The +120VDC indicator LED D940 was unlit. > LED indicator diode for "protect-mode" D912 was flashing. > HOT good. > Cause was a small blue 2KV scan disc cap hidden under the larger ones > had arced internally: C707 "102 / 2KV". > C707 replaced, E994 replaced fixed set. > Phil Bader > > -- > > Philip Bader > Jan Phyl TV Inc. (estab. 1976) > 3420 Recker Hwy. Winter Haven, Fl. 33880 > Fax (863) 299-8821 > email: tjanphyl@xxxxxxxxxxxxxxx > > -------------------------------------------------------------------------- --- > This Email List is Public. Remove: http://www.tech-assist.org/remove.htm > Lost Password: http://www.tech-assist.org and select "Login Problems?". > Email Archives: //www.freelists.org/archives/techassist/ > ----------------------------------------------------------------------------- This Email List is Public. Remove: http://www.tech-assist.org/remove.htm Lost Password: http://www.tech-assist.org and select "Login Problems?". Email Archives: //www.freelists.org/archives/techassist/