[TechAssist] Hitachi 50UX8B in shut down. D912 protect diode flashing, FIX

  • From: Phil Bader <tjanphyl@xxxxxxxxxxxxxxx>
  • To: "techassist@xxxxxxxxxxxxx" <techassist@xxxxxxxxxxxxx>
  • Date: Thu, 31 Mar 2005 10:53:31 -0500

Submitted by local shop.
Powered on this set, smelled something like a HV arc.
Pico fuse E994 open
The +120VDC indicator LED D940 was unlit.
LED indicator diode for "protect-mode" D912 was flashing.
HOT good.
Cause was a small blue 2KV scan disc cap hidden under the larger ones 
had arced internally: C707 "102 / 2KV".
C707  replaced, E994 replaced fixed set.