[SI-LIST] de-embedding fixture

  • From: Kevin Li <swagguy10@xxxxxxxxx>
  • To: si-list@xxxxxxxxxxxxx
  • Date: Thu, 15 Sep 2011 03:12:13 -0400

Hi, experts,
I was doing differential measurement on VNA and trying to de-embed fixtures.
I saved SDD21 data of the fixture in "memory" and tested the DUT cascading
with the fixture and saved that as "Data". By clicking "Data/Memory" I could
get the SDD21 for the DUT only.

I guess de-embedding SDD11 and SCD21 could not be done by similar method.
What do you guys think? I would be glad to know whether we can de-embed
SDD11 and SCD21 without PLTS.

Thanks.
Kevin


------------------------------------------------------------------
To unsubscribe from si-list:
si-list-request@xxxxxxxxxxxxx with 'unsubscribe' in the Subject field

or to administer your membership from a web page, go to:
//www.freelists.org/webpage/si-list

For help:
si-list-request@xxxxxxxxxxxxx with 'help' in the Subject field


List technical documents are available at:
                http://www.si-list.net

List archives are viewable at:     
                //www.freelists.org/archives/si-list
 
Old (prior to June 6, 2001) list archives are viewable at:
                http://www.qsl.net/wb6tpu
  

Other related posts: