If you are connecting an SSTL2 Class I device to a Class II device in a point-point configuration, parallel terminating at either end is likely to be sub-optimal. Series termination is likely to offer better reflection performance unless your interconnect length is close to half a bit time. Thanks, Vinu valleybird03 wrote: >Hi, > >When connecting one SSTL2 ClassI device with one SSTL2 CLassIi device, >do we have to add 50ohm parallel resisor to 1.25V at near end of >Class I or we can skip the 50ohm parallel resistor at near end of >Class II? > >Thanks > >------------------------------------------------------------------ >To unsubscribe from si-list: >si-list-request@xxxxxxxxxxxxx with 'unsubscribe' in the Subject field > >or to administer your membership from a web page, go to: >//www.freelists.org/webpage/si-list > >For help: >si-list-request@xxxxxxxxxxxxx with 'help' in the Subject field > >List archives are viewable at: > //www.freelists.org/archives/si-list >or at our remote archives: > http://groups.yahoo.com/group/si-list/messages >Old (prior to June 6, 2001) list archives are viewable at: > http://www.qsl.net/wb6tpu > > > > > ------------------------------------------------------------------ To unsubscribe from si-list: si-list-request@xxxxxxxxxxxxx with 'unsubscribe' in the Subject field or to administer your membership from a web page, go to: //www.freelists.org/webpage/si-list For help: si-list-request@xxxxxxxxxxxxx with 'help' in the Subject field List archives are viewable at: //www.freelists.org/archives/si-list or at our remote archives: http://groups.yahoo.com/group/si-list/messages Old (prior to June 6, 2001) list archives are viewable at: http://www.qsl.net/wb6tpu