[SI-LIST] Re: Regarding Peak transient current calculation

  • From: Sagar AGRAWAL <saga.agrawal@xxxxxxxxx>
  • To: naveenchandra.swamy@xxxxxxxxx
  • Date: Fri, 21 Jul 2017 17:41:59 +0530

Hello Naveen,
While calculating your target impedance you have to use imax/2 which is
your transient current.
Zo=(vdd*0.03)/I(transient)

Where I (transient)=Imax/2

Thanks.
Sagar A
On 21-Jul-2017 17:35, "naveenchandra.swamy@xxxxxxxxx" <
naveenchandra.swamy@xxxxxxxxx> wrote:

Hello Experts,
If you don't mind, I need a small help from you regarding Peak transient
current calculation.

When we are doing AC coupling analysis (decoupling analysis), as we know
that, Zotarget formulae =VDD (V)*ripple (%)/Peak transient Current(A). So,
here I did one calculation for the same with some assumptions as follow
below.

Example:
Inputs: VDD=1V, 3% ripple=.003,Imax , Peak transient current=?, since I
don't have peak transient current details, I am calculating theoretically
i.e., 0.5*Imax. I did some calculation as follow below. Then, for our case
Peak transient current would be 0.5*1A==0.5A.

The main concern is that, When we are applying/feeding inputs to the
simulation environment (EDA tools), whether we need to feed just 0.5A as
peak transient current or Imax+ peak transient current, i.e. 1A+0.5A=1.5A
as peak transient current? Can you please help me and give more technical
information's on this?

Thanks,
Naveenchandra V
M +91-7760746060,

The information contained in this electronic message and any attachments
to this message are intended for the exclusive use of the addressee(s) and
may contain proprietary, confidential or privileged information. If you are
not the intended recipient, you should not disseminate, distribute or copy
this e-mail. Please notify the sender immediately and destroy all copies of
this message and any attachments. WARNING: Computer viruses can be
transmitted via email. The recipient should check this email and any
attachments for the presence of viruses. The company accepts no liability
for any damage caused by any virus transmitted by this email.
www.wipro.com

------------------------------------------------------------------
To unsubscribe from si-list:
si-list-request@xxxxxxxxxxxxx with 'unsubscribe' in the Subject field

or to administer your membership from a web page, go to:
//www.freelists.org/webpage/si-list

For help:
si-list-request@xxxxxxxxxxxxx with 'help' in the Subject field


List forum  is accessible at:
               http://tech.groups.yahoo.com/group/si-list

List archives are viewable at:
                //www.freelists.org/archives/si-list

Old (prior to June 6, 2001) list archives are viewable at:
                http://www.qsl.net/wb6tpu





------------------------------------------------------------------
To unsubscribe from si-list:
si-list-request@xxxxxxxxxxxxx with 'unsubscribe' in the Subject field

or to administer your membership from a web page, go to:
//www.freelists.org/webpage/si-list

For help:
si-list-request@xxxxxxxxxxxxx with 'help' in the Subject field


List forum  is accessible at:
               http://tech.groups.yahoo.com/group/si-list

List archives are viewable at:     
                //www.freelists.org/archives/si-list
 
Old (prior to June 6, 2001) list archives are viewable at:
                http://www.qsl.net/wb6tpu
  

Other related posts: