Follow the current.  Your first line of defense against unwanted noise 
in common impedance paths is placement.  The second line of defense is 
selective moating.  Moating is only applicable when specific currents 
would traverse a common impedance path that would result in an 
unacceptably high voltage disturbance without them.  Moating is a lot 
like ferrite beads.  There are times when a little bit of voided etch 
can do very nice things.  They are not a panacea.  They are every bit as 
capable of introducing problems as fixing them.  Just like there are a 
lot of appnotes that call for overuse and misuse of ferrite beads, there 
are lots of appnotes that call for moats where they are not appropriate 
or are even harmful.  If you plan your placement, particularly of the 
bypass components carefully,  you shouldn't need moats with those 
modules.  If you are lining up a bunch of those modules side by side, 
selective moating to keep thepin 1/21 ... 17 side of one part's common 
separated from the adjacent part's pin 10/11...15 side is a reasonable 
idea.  If you have a bunch of signal traces running underneath these 
things then you may wish to rethink your placement, or get more creative.

Steve.



On 12/12/2011 7:02 AM, Tomas Carlsson wrote:
> Hello,
> This is a question on the popular topic whether to stitch different grounds
> (analog / digital / power) together or not.
>
> I am looking in the datasheet and app notes for a couple of Digital DC/DC
> Converter Modules (17A or 6A):
> http://www.intersil.com/data/fn/fn7914.pdf
> http://www.intersil.com/data/fn/fn6852.pdf
>
> It is recommended to connect the analog/signal ground (SGND) island to the
> power ground (PGND) in *one place only*.
>
> I have a 12 layer stack-up with 4-5 ground planes. I plan to stitch all
> ground points (regardless SGND / PGND / DGND) together through vias close
> to each ground pad to avoid creating plane cuts. This will in effect stitch
> SGND to PGND and make the design simpler. What are your thoughts on this?
> Is it a good or bad idea to make the entire DC/DC module see the same
> ground?
>
> Thanks,
> Tomas Carlsson
>
>
> ------------------------------------------------------------------
> To unsubscribe from si-list:
> si-list-request@xxxxxxxxxxxxx with 'unsubscribe' in the Subject field
>
> or to administer your membership from a web page, go to:
> //www.freelists.org/webpage/si-list
>
> For help:
> si-list-request@xxxxxxxxxxxxx with 'help' in the Subject field
>
>
> List technical documents are available at:
>                  http://www.si-list.net
>
> List archives are viewable at:
>               //www.freelists.org/archives/si-list
>
> Old (prior to June 6, 2001) list archives are viewable at:
>               http://www.qsl.net/wb6tpu
>
>
>


-- 
Steve Weir
IPBLOX, LLC
150 N. Center St. #211
Reno, NV  89501
www.ipblox.com

(775) 299-4236 Business
(866) 675-4630 Toll-free
(707) 780-1951 Fax


------------------------------------------------------------------
To unsubscribe from si-list:
si-list-request@xxxxxxxxxxxxx with 'unsubscribe' in the Subject field

or to administer your membership from a web page, go to:
//www.freelists.org/webpage/si-list

For help:
si-list-request@xxxxxxxxxxxxx with 'help' in the Subject field


List technical documents are available at:
                http://www.si-list.net

List archives are viewable at:     
                //www.freelists.org/archives/si-list
 
Old (prior to June 6, 2001) list archives are viewable at:
                http://www.qsl.net/wb6tpu
  

Other related posts: