[racktables-users] Re: SNMP Support for HP/Compaq servers

  • From: Killsystem <killsystem@xxxxxxxxxxxxxxxx>
  • To: racktables-users@xxxxxxxxxxxxx
  • Date: Mon, 10 Nov 2008 17:28:30 +0100

Hi Luis,

what exactly so you wanna see?
There is, at the moment, no real implementation for snmp on server objects.
I only added a new attribute called "Productnumber" in my environment,
that's all.

gretz Killsystem

On Mon, 10 Nov 2008 09:06:56 -0600, Luis Fernando Lacayo
<lflacayo@xxxxxxxxxxxxx> wrote:
> Can you send me a screen print of how this looks in the object
> configuration, it sounds like something we might like to use...  
> 
> thanks, 
> 
> Luis
> 
> On Thu, 2008-10-16 at 10:02 +0200, killsystem wrote:
> 
>> Hi,
>> 
>> Since most of us which use HP/Compaq servers install the Insight Agents
>> to
>> manage them and could find this add-on very helpfull.
>> Is it possible to make an "SNMP Get" function for server equipment as
>> well?
>> Those information could be obtained easily:
>> Serialnumber/Barcode: 
>>  * OID: 1.3.6.1.4.1.232.2.2.2.1.0
>>  * Type: String
>>  * Example: 1.3.6.1.4.1.232.2.2.2.1.0 = OCTET STRING XXX00000XX
>> Asset Tag:
>>  * OID: 1.3.6.1.4.1.232.2.2.2.3.0
>>  * Type: String
>>  * Example: 1.3.6.1.4.1.232.2.2.2.3.0 = OCTET STRING MY_ASSET_TAG
>> Productnumber (I added this in my environment):
>>  * OID: 1.3.6.1.4.1.232.2.2.2.6.0
>>  * Type: String
>>  * Example: 1.3.6.1.4.1.232.2.2.2.6.0 = OCTET STRING 418315-421
>> 
>> I think the first and second apply to every racktable installation, but
>> the
>> third one only to mine or anybody else who has added the productnumber
as
>> field.
>> But this would be a start to support every hardware vendor if he
supports
>> this information through snmp.
>> 
>> Gretz Fabian
>> 
>> 
> 
>

Other related posts: