Anyone know the target reflection densities of the Agfa step wedge? I'm comparing one side by side to Stouffer's (both are 21 steps), and step 1 is distinctly different between the two. On Stouffer's wedge, Step 1 looks paper white (whiter than my papers, anyway); on Agfa's, Step 1 is Zone VIII reflectance to my eyes. I'm assuming Stouffer's Step 1 is close to its specification of 0.05 density, but it's not calibrated. I'm also assuming Agfa's Step 1 is close to 0.1, because its density does appear to be between Stouffer's #1 (.05) and Stouffer's step 2 (.15). I wonder if anyone has advice about which step to use to determine paper scale: Agfa Step 1 or Stouffer Step 2, or something else? If I had a reflection densitometer it wouldn't be an issue. Using my eyes alone, I'm tempted to use Agfa Step 1 as the best Zone VIII reflectance. BTW, anyone know why Stouffer begins at 0.05 and then jumps to 1.5--- doesn't that completely jump over the usual density of Zone VIII, or 0.1 that most of us are interested in? Thanks. J.R. Stewart Leesburg, VA ============================================================================================================= To unsubscribe from this list, go to www.freelists.org and logon to your account (the same e-mail address and password you set-up when you subscribed,) and unsubscribe from there.