RE: Making OCR / VD Visible to BOTH DB Server (SUN) Nodes ... Basic Qs

  • From: VIVEK_SHARMA <VIVEK_SHARMA@xxxxxxxxxxx>
  • To: "oracle-l@xxxxxxxxxxxxx" <oracle-l@xxxxxxxxxxxxx>
  • Date: Tue, 17 Jul 2007 21:23:56 +0530

Folks

How are the Oracle Cluster Registry (OCR) & Voting Disk (VD) device files to be 
Made Concurrently VISIBLE / Shareable to BOTH Database (Solaris 10) Nodes?
Five RAW devices (2 OCR & 3 VD) of 200MB each were created only on the Node 
1(Master node).

Aim is to setup a 2 Node ASM RAC.

Qs To make the OCR / VD devices visible to the Other / 2nd Node which of the 
following 3 Options is applicable:-

 1.  Solaris/SUN Cluster Setup needed on BOTH Nodes
 2.  Issue of some Solaris Commands (On HP-UX vgexport, vgimport commands are 
used to export & import the respective raw devices from the 1st node to the 
2nd.)
 3.  CRS setup automatically make the OCR / VD devices created only on the 1st 
(Master) Node visible to the 2nd Node without need for any additional O.S. 
Commands

NOTE - The Storage Box is connected to BOTH the Nodes thru a Switch.
NOTE - External Redundancy to be used for ASM DB Setup.

Cheers & Thanks

Vivek

P.S.

Configuration:-
Solaris 10
Oracle 10gR2

Following commands used for creation of OCR / VD device files only on the 1st 
(master) Node:-

Step 1 - Command for creating the Raw Devices


dd if=/dev/zero of=/asmdata/voting/asm_vote1 bs=1k count=200000
O/P
200000+0 records in
200000+0 records out


Step 2 - Command for creating loop devices so that a character device can be 
associated with a file



lofiadm -a /asmdata/voting/asm_vote1

O/P: /dev/lofi/1


Step 3 - Command for creating the respective character file to access the file
mknod /asmdata/voting/vdiskvote1 c 147 1




**************** CAUTION - Disclaimer *****************
This e-mail contains PRIVILEGED AND CONFIDENTIAL INFORMATION intended solely 
for the use of the addressee(s). If you are not the intended recipient, please 
notify the sender by e-mail and delete the original message. Further, you are 
not to copy, disclose, or distribute this e-mail or its contents to any other 
person and any such actions are unlawful. This e-mail may contain viruses. 
Infosys has taken every reasonable precaution to minimize this risk, but is not 
liable for any damage you may sustain as a result of any virus in this e-mail. 
You should carry out your own virus checks before opening the e-mail or 
attachment. Infosys reserves the right to monitor and review the content of all 
messages sent to or from this e-mail address. Messages sent to or from this 
e-mail address may be stored on the Infosys e-mail system.
***INFOSYS******** End of Disclaimer ********INFOSYS***

Other related posts: