[optimal] Re: FA for ONH Drusen?

  • From: CPMC Ophthalmic Diagnostic Center <cpmceyelab@xxxxxxxxxxxxxxxx>
  • To: "optimal@xxxxxxxxxxxxx" <optimal@xxxxxxxxxxxxx>
  • Date: Wed, 10 Oct 2018 20:51:49 +0000

Oh yes, the VF of course
That's like a pulse and respiration in our field
Just about everyone gets one



Denice Barsness, CRA, COMT, CDOS, FOPS
CPMC Dept of Ophthalmology/ The Eye Institute
Ophthalmic Diagnostic Services
711 Van Ness Avenue Suite 250
San Francisco CA 94109
415-600-5781
FAX 415-558-7011

From: Barsness, Denice
Sent: Wednesday, October 10, 2018 1:43 PM
To: CPMC Ophthalmic Diagnostic Center <cpmceyelab@xxxxxxxxxxxxxxxx>
Subject: FW: [optimal] Re: FA for ONH Drusen?


________________________________
From: optimal-bounce@freelists.orgOn<mailto:optimal-bounce@freelists.orgOn
Behalf OfSandor Ferenczy
Sent: Wednesday, October 10, 2018 1:41:51 PM (UTC-08:00) Pacific Time (US & 
Canada)
To: optimal@xxxxxxxxxxxxx<mailto:optimal@xxxxxxxxxxxxx>
Subject: [optimal] Re: FA for ONH Drusen?
With IIH (the dx formerly knows as pseudotumor cerebri) intraocular findings 
would be limited to VF defects & papilledema from the increase intracranial 
pressure. Extraocular, the eyes may turn inward.

Spinal tap & CSF pressure test need to be done.

-sandor

On Wed, Oct 10, 2018 at 4:11 PM Stuart Alfred 
<stuart.alfred@xxxxxxxxx<mailto:stuart.alfred@xxxxxxxxx>> wrote:
Denice,
I am unaware of the IIH testing, more than drusen.   Prior to communication 
with the physician, I want the Ateam's advice.

 Understood re. either modality of FA being unnecessary for drusen, but is it 
useful for IIH detection?

Thanks.
Stuart Alfred / 317-517-9455 / 
stuart.alfred@xxxxxxxxx<mailto:stuart.alfred@xxxxxxxxx>
Board of Education - OPS {Equipment Chair} - 
www.opsweb.org<https://na01.safelinks.protection.outlook.com/?url=http%3A%2F%2Fwww.opsweb.org&data=02%7C01%7Cbarsned%40sutterhealth.org%7Cc3b8b41a19a042444a4208d62ef0f270%7Caef453eadaa243e0be62818066e9ff63%7C0%7C0%7C636748009745162325&sdata=W06q8UG32ex9T4mBqSSM0ay6qfVzxfxO1tkJPUmS8sU%3D&reserved=0>




On Wed, Oct 10, 2018 at 2:10 PM CPMC Ophthalmic Diagnostic Center 
<cpmceyelab@xxxxxxxxxxxxxxxx<mailto:cpmceyelab@xxxxxxxxxxxxxxxx>> wrote:
Why are we doing FA on ON Drusen
The definitive pathognomonic testing would be FAF and US in that combo
Often, there are not enough fluorophores for FAF to smoke them out
Sometimes, with US, they are not large enough for the 150 micron resolution
Combo of both works wonders
( reference my OPS talk "Imaging for ONH Drusen, and Histopathology of the 
Human Eye; Hogan )

Here, unless there is something about the history I am missing, we would NOT do 
an FA

Denice

Denice Barsness, CRA, COMT, CDOS, FOPS
CPMC Dept of Ophthalmology/ The Eye Institute
Ophthalmic Diagnostic Services
711 Van Ness Avenue Suite 250
San Francisco CA 94109
415-600-5781
FAX 415-558-7011

From: Barsness, Denice
Sent: Wednesday, October 10, 2018 7:04 AM
To: CPMC Ophthalmic Diagnostic Center 
<cpmceyelab@xxxxxxxxxxxxxxxx<mailto:cpmceyelab@xxxxxxxxxxxxxxxx>>
Subject: FW: [**External**] [optimal] More pediatric angiography questions


________________________________
From: optimal-bounce@freelists.orgOn<mailto:optimal-bounce@freelists.orgOn
Behalf OfStuart Alfred
Sent: Wednesday, October 10, 2018 7:02:08 AM (UTC-08:00) Pacific Time (US & 
Canada)
To: OPTIMAL
Subject: [**External**] [optimal] More pediatric angiography questions

WARNING: This email originated outside of the Sutter Health email system!
DO NOT CLICK links if the sender is unknown and never provide your User ID or 
Password.



My satellite office is being sought out by the Riley Hospital ophthalmology 
team for help with pt. testing.  This is a personal accomplishment for me.  
Really proud, and humbled.

Two upcoming visits:
14 year old. Weight:  100lb    Working diagnosis: IIH, ON drusen
13 year old.  Weight: 100lb   Working Dx: ON drusen

My prescription of testing OU [stricly Spectralis FA &/ or Cirrus 5000] would 
involve:
Fasting 2 hours prior
Spectralis OCT ON - ONH button [73 sec., 60ym] art at 9
ON photos - IR 30degree, RF//BR 30 deg., FAF 30 & 20 degrees

FA oral, using 10% AK-FLUOR
convert weight for admin. using referenced calculations. i.e.  2 vials 10%  
5mL, into 3.5 oz. apple juice.
start  timer upon pat. consuming.  At 2 minutes start FA using 30 degree lens, 
laser at 95% sensitivity.  Acquire images every 3 minutes until 15 min. So OU 
at 2, 5, 8, 11, 14mins.

Any advice OPTIMAL?  Please!
I don't see any reason to choose IV over oral.?

Thanks,

Stuart Alfred / 317-517-9455 / 
stuart.alfred@xxxxxxxxx<mailto:stuart.alfred@xxxxxxxxx>
Board of Education - OPS {Equipment Chair} - 
www.opsweb.org<https://na01.safelinks.protection.outlook.com/?url=http%3A%2F%2Fwww.opsweb.org&data=02%7C01%7Cbarsned%40sutterhealth.org%7Cc3b8b41a19a042444a4208d62ef0f270%7Caef453eadaa243e0be62818066e9ff63%7C0%7C0%7C636748009745162325&sdata=W06q8UG32ex9T4mBqSSM0ay6qfVzxfxO1tkJPUmS8sU%3D&reserved=0>

Other related posts: