[ibis-macro] question about Rx_Clock_Recoery_Mean

  • From: <fangyi_rao@xxxxxxxxxxx>
  • To: <wkatz@xxxxxxxxxx>, <ibis-macro@xxxxxxxxxxxxx>
  • Date: Sun, 10 Jan 2010 22:23:54 -0700

Hi, Walter;

 

Can you clarify the functionality of the new parameter Rx_Clock_Recovery_Mean? 
My understanding is that 

 

If its Usage is In, signal is sampled at 0.5*bit_time after a clock time as 
stated on page 29 in the BIRD.

If its Usage is Info or Out, signal is sampled at (0.5*bit_time + 
Rx_Clock_Recovery_Mean) after a clock time.

 

Thanks,

Fangyi

 

Other related posts:

  • » [ibis-macro] question about Rx_Clock_Recoery_Mean - fangyi_rao