[ibis-macro] Re: [ibis-interconn] Re: IBIS Interconnect BIRD - A_gnd Examples for IBIS-ISS

  • From: "Bob Ross" <bob@xxxxxxxxxxxxxxxxx>
  • To: <ibis-interconn@xxxxxxxxxxxxx>
  • Date: Mon, 15 Jan 2018 14:08:51 -0800

Hi Arpad,

 

I understand and agree with the interpretations below.

 

A_gnd is not needed if there already exists an internal node 0 in the
subcircuit.

 

The A_gnd terminal_type could be used to connect to a vdd or vss or all rail
nodes in a subcircuit terminal line to  node 0.

 

While this might not have been the original goal, A_gnd can be used to short
to "0" any other subcircuit terminal line node (including those associated
with I/O's, as Example 13 shows) for a reduced Interconnect Model.

 

Bob

 

From: ibis-interconn-bounce@xxxxxxxxxxxxx
[mailto:ibis-interconn-bounce@xxxxxxxxxxxxx] On Behalf Of Muranyi, Arpad
Sent: Monday, January 15, 2018 1:51 PM
To: ibis-interconn@xxxxxxxxxxxxx
Cc: 'IBIS-ATM'
Subject: [ibis-interconn] Re: IBIS Interconnect BIRD - A_gnd Examples for
IBIS-ISS

 

Bob,

 

To answer your question in a different way, I checked in the IBIS-ISS spec,

node0 and its synonyms are still interpreted as the global ground:

 



 

On the other hand, IBIS-ISS does not support global parameters:

 



 

So YES to the global node0, bit NO to global parameters.

 

Arpad

=============================================

 

From: Muranyi, Arpad 
Sent: Monday, January 15, 2018 3:40 PM
To: ibis-interconn@xxxxxxxxxxxxx
Cc: 'IBIS-ATM' <ibis-macro@xxxxxxxxxxxxx>
Subject: RE: [ibis-interconn] Re: IBIS Interconnect BIRD - A_gnd Examples
for IBIS-ISS

 

My understanding is that A_gnd is the same thing as node0, GND, GND! and

all of its synonyms.  So with that in mind, I don't see why someone would

use A_gnd on a terminal line if that subcircuit terminal is also grounded
from

the inside of the subcircuit.

 

Thanks,

 

Arpad

=============================================================

 

From: ibis-interconn-bounce@xxxxxxxxxxxxx
[mailto:ibis-interconn-bounce@xxxxxxxxxxxxx] On Behalf Of Bob Ross
Sent: Monday, January 15, 2018 2:22 PM
To: ibis-interconn@xxxxxxxxxxxxx
Cc: 'IBIS-ATM' <ibis-macro@xxxxxxxxxxxxx>
Subject: [ibis-interconn] Re: IBIS Interconnect BIRD - A_gnd Examples for
IBIS-ISS

 

Arpad,

 

You raise some good points.

 

Do we assume that if a (global)  node 0 is used in a .iss, it is
automatically connected to the similar node 0?

(So we do not need Example 14.)

 

Bob

 

From: ibis-interconn-bounce@xxxxxxxxxxxxx
[mailto:ibis-interconn-bounce@xxxxxxxxxxxxx] On Behalf Of Muranyi, Arpad
Sent: Monday, January 15, 2018 11:22 AM
To: ibis-interconn@xxxxxxxxxxxxx
Cc: IBIS-ATM
Subject: [ibis-interconn] Re: IBIS Interconnect BIRD - A_gnd Examples for
IBIS-ISS

 

Bob,

 

Thanks for the examples.  I wonder about Example 14.  What is the purpose of

having a subcircuit definition terminal connected to node0 on the outside
(on

the terminal line) when it is also connected to node0 on the inside of the

subcircuit?  By the way, since we can't have a .connect statement inside the

subcircuit, the only way to do that would be by using a 0V DC source or a
small

value resistor.  But an ideal source will most likely end up with a "Voltage
source,

inductor loop" error message, so the only option is a small valued resistor.
But

why would someone want to do that?

 

Maybe I don't understand it, but I think we could remove Example 14.

 

Thanks,

 

Arpad

================================================================

 

From: ibis-interconn-bounce@xxxxxxxxxxxxx
[mailto:ibis-interconn-bounce@xxxxxxxxxxxxx] On Behalf Of Bob Ross
Sent: Monday, January 15, 2018 1:04 PM
To: ibis-interconn@xxxxxxxxxxxxx
Cc: IBIS-ATM <ibis-macro@xxxxxxxxxxxxx>
Subject: [ibis-interconn] IBIS Interconnect BIRD - A_gnd Examples for
IBIS-ISS

 

All,

 

Attached are two examples and related text in BIRD189_draft15_v6.

 

I want to check if my interpretation is correct on these points that are
also mentioned in BIRD189.

 

-          A_gnd can be used to short I/O nodes to ground at several
terminal lines (Example 13)

-          A new node on the .subckt line can be created that shorts to an
internal node 0 (since we do not allow "0" to be a node name (Example 14).
Node 0 is global and does not have to be exposed.

-          No example is shown for File_TS since the rule is clear that only
the N+1 terminal line can optionally have A_gnd as a reference

 

Also, we should use lower case "node 0" in BIRD189.

 

Bob

 

--

 

Bob Ross

Teraspeed Labs

www.teraspeedlabs.com <http://www.teraspeedlabs.com/

bob@xxxxxxxxxxxxxxxxx

Direct: 503-246-8048

Office: 971-279-5325

 

PNG image

PNG image

Other related posts: