[ibis-macro] Re: [ibis-interconn] Re: IBIS Interconnect BIRD - A_gnd Examples for IBIS-ISS

  • From: "Bob Ross" <bob@xxxxxxxxxxxxxxxxx>
  • To: <ibis-interconn@xxxxxxxxxxxxx>
  • Date: Mon, 15 Jan 2018 12:21:32 -0800

Arpad,

 

You raise some good points.

 

Do we assume that if a (global)  node 0 is used in a .iss, it is
automatically connected to the similar node 0?

(So we do not need Example 14.)

 

Bob

 

From: ibis-interconn-bounce@xxxxxxxxxxxxx
[mailto:ibis-interconn-bounce@xxxxxxxxxxxxx] On Behalf Of Muranyi, Arpad
Sent: Monday, January 15, 2018 11:22 AM
To: ibis-interconn@xxxxxxxxxxxxx
Cc: IBIS-ATM
Subject: [ibis-interconn] Re: IBIS Interconnect BIRD - A_gnd Examples for
IBIS-ISS

 

Bob,

 

Thanks for the examples.  I wonder about Example 14.  What is the purpose of

having a subcircuit definition terminal connected to node0 on the outside
(on

the terminal line) when it is also connected to node0 on the inside of the

subcircuit?  By the way, since we can't have a .connect statement inside the

subcircuit, the only way to do that would be by using a 0V DC source or a
small

value resistor.  But an ideal source will most likely end up with a "Voltage
source,

inductor loop" error message, so the only option is a small valued resistor.
But

why would someone want to do that?

 

Maybe I don't understand it, but I think we could remove Example 14.

 

Thanks,

 

Arpad

================================================================

 

From: ibis-interconn-bounce@xxxxxxxxxxxxx
[mailto:ibis-interconn-bounce@xxxxxxxxxxxxx] On Behalf Of Bob Ross
Sent: Monday, January 15, 2018 1:04 PM
To: ibis-interconn@xxxxxxxxxxxxx
Cc: IBIS-ATM <ibis-macro@xxxxxxxxxxxxx>
Subject: [ibis-interconn] IBIS Interconnect BIRD - A_gnd Examples for
IBIS-ISS

 

All,

 

Attached are two examples and related text in BIRD189_draft15_v6.

 

I want to check if my interpretation is correct on these points that are
also mentioned in BIRD189.

 

-          A_gnd can be used to short I/O nodes to ground at several
terminal lines (Example 13)

-          A new node on the .subckt line can be created that shorts to an
internal node 0 (since we do not allow "0" to be a node name (Example 14).
Node 0 is global and does not have to be exposed.

-          No example is shown for File_TS since the rule is clear that only
the N+1 terminal line can optionally have A_gnd as a reference

 

Also, we should use lower case "node 0" in BIRD189.

 

Bob

 

--

 

Bob Ross

Teraspeed Labs

www.teraspeedlabs.com <http://www.teraspeedlabs.com/

bob@xxxxxxxxxxxxxxxxx

Direct: 503-246-8048

Office: 971-279-5325

 

Other related posts: