[ibis-macro] What is "Local Ground", how are all voltage measurements made

  • From: Walter Katz <wkatz@xxxxxxxxxx>
  • To: "IBIS-ATM" <ibis-macro@xxxxxxxxxxxxx>
  • Date: Tue, 17 Jan 2017 16:13:53 -0500 (EST)

All,

 

I think that IBIS should simply state:

 

All voltage measurements at a buffer shall be made relative to a "Local
Ground" node.  

 

The "Local Ground" is defined as any Rail Terminal that has a value of 0.0
volts in DUT conditions. 

*         If there is no Rail Terminal that has a value of 0.0 volts in
DUT conditions, then

o   A component pin rail signal name that has a 0.0V DUT value, then that
signal name shall be "Local Ground". 

*  If there is no component pin that has a DUT value of 0.0V, then
simulator Node 0 shall be the reference voltage for all voltage
measurements.

 

Walter

 

Walter Katz

 <mailto:wkatz@xxxxxxxxxx> wkatz@xxxxxxxxxx

Phone 303.449-2308

Mobile 303.335-6156

Other related posts: