[ibis-macro] Re: Usage type of jitter parameters in ibis5.1

  • From: Mike LaBonte <mike@xxxxxxxxxxx>
  • To: "fangyi_rao@xxxxxxxxxxx" <fangyi_rao@xxxxxxxxxxx>
  • Date: Fri, 5 Jul 2013 09:25:23 -0400

Walter can answer the direct question, but for background Tx_Jitter
and Tx_DCD were changed to Info only in BIRD 123.5
(http://www.eda.org/ibis/birds/bird123.5.docx).

Mike

On Tue, Jul 2, 2013 at 7:03 PM,  <fangyi_rao@xxxxxxxxxxx> wrote:
> Walter;
>
>
>
> Can you remind me why Out is not allowed for Tx_DCD and Tx_Jitter in 6.0?
>
>
>
> Thanks,
>
> Fangyi
>
>
>
> From: Walter Katz [mailto:wkatz@xxxxxxxxxx]
> Sent: Tuesday, July 02, 2013 4:01 PM
> To: RAO,FANGYI (A-USA,ex1); ibis-macro@xxxxxxxxxxxxx
> Subject: RE: [ibis-macro] Usage type of jitter parameters in ibis5.1
>
>
>
> Fangyi,
>
>
>
> In IBIS 6.0 Draft:
>
>
>
> Parameter:         Tx_DCD
>
> Required:            No
>
> Descriptors:
>
> Usage:                  Info,  (Out permitted only for AMI_Version 5.0 and
> 5.1)
>
> Type:                     Float, UI
>
> Format:                                Value, Range, Corner, List,
> Increment, Steps
>
> Default:                                <numeric_literal>
>
> Description:        <string>
>
>
>
> Parameter:         Tx_Jitter
>
> Required:            No
>
> Descriptors:
>
> Usage:                  Info (, Out permitted only for AMI_Version 5.0 and
> 5.1)
>
> Type:                     Float, UI
>
> Format:                                Gaussian, Dual-Dirac, DjRj, Table
>
> Default:                (Illegal)
>
> Description:        <string>
>
>
>
>
>
> Rx_Clock_PDF and Rx_Receiver_Sensitivity are Info and Out.
>
>
>
> Walter
>
>
>
> -----Original Message-----
> From: ibis-macro-bounce@xxxxxxxxxxxxx
> [mailto:ibis-macro-bounce@xxxxxxxxxxxxx] On Behalf Of fangyi_rao@xxxxxxxxxxx
> Sent: Tuesday, July 02, 2013 6:55 PM
> To: ibis-macro@xxxxxxxxxxxxx
> Subject: [ibis-macro] Usage type of jitter parameters in ibis5.1
>
>
>
> A question regarding usage type of jitter parameters came up in today's ATM.
> I checked the IBIS 5.1 spec and found that following reserved parameters
>
>
>
> Tx_DCD
>
> Tx_Jitter
>
> Rx_Clock_PDF
>
> Rx_Receiver_Sensitivity
>
>
>
> are allowed to have usage type of Info or Out. So their values can be
> returned by AMI_Init.
>
>
>
> Fangyi
>
>
>
> ---------------------------------------------------------------------
>
> IBIS Macro website  :  http://www.eda.org/pub/ibis/macromodel_wip/
>
> IBIS Macro reflector:  //www.freelists.org/list/ibis-macro
>
> To unsubscribe send an email:
>
>   To: ibis-macro-request@xxxxxxxxxxxxx
>
>   Subject: unsubscribe
>
>
---------------------------------------------------------------------
IBIS Macro website  :  http://www.eda.org/pub/ibis/macromodel_wip/
IBIS Macro reflector:  //www.freelists.org/list/ibis-macro
To unsubscribe send an email:
  To: ibis-macro-request@xxxxxxxxxxxxx
  Subject: unsubscribe

Other related posts: