MM. Almost. If (Type Float) Row Time (seconds) Probability, if (Type UI) then Row UI Probability. Walter From: ibis-editorial-bounce@xxxxxxxxxxxxx [mailto:ibis-editorial-bounce@xxxxxxxxxxxxx] On Behalf Of Mirmak, Michael Sent: Wednesday, April 25, 2012 3:53 PM To: ibis-editorial@xxxxxxxxxxxxx Subject: [ibis-editorial] Table format for Tx_Jitter and Rx_Clock_PDF as Reserved Parameters Is the Table format for the jitter Reserved Parameters Tx_Jitter and Rx_Clock_PDF assumed to be *always* organized as shown in the examples given? For example, in Tx_Jitter, Table is organized as: Row Time Probability . where Row is an integer, Time is a float in seconds and Probability is a float without units. We *do* state that, "If Table is used for a Reserved Parameter, the rules for the number of columns and their meaning are described in the Reserved_Parameters section." However, the arrangement is never actually stated, but only shown in the examples. - MM