I'm familiar with variable reluctance sensors. I believe that's what you're
referring to. They produce a signal that increases in frequency and amplitude
as the rpms increase. Signal conditioning is required to prevent the high
voltage produced from exceeding the limits of a uC.
-- Bob
-----Original Message-----
From: arocket-bounce@xxxxxxxxxxxxx [mailto:arocket-bounce@xxxxxxxxxxxxx]
On Behalf Of Monroe L. King Jr.
Sent: Thursday, November 19, 2015 2:53 PM
To: Arocket <arocket@xxxxxxxxxxxxx>
Subject: [AR] Speed sensor for pump shaft
Anyone have any experience with a magnetic speed sensor? This type of
sensor you magnetize the end of your shaft with a permanent magnet and
the flux produced is used to get the rotational value.