Hello,  I got this message creating  icm form my laptop LCD,
I used this targetgen to create a large patchset (2000) and now using colprof with this arguments

colprof.exe -v -qu -t p -al ..\data\vaio_lcd2k -S ..\ref\sRGB.icm

It shows this warning:

Black point XYZ = 0.002538 0.002376 0.003633, Lab = 2.146549 0.997709 -3.158702
Display Luminance = 80.324745
colprof.exe: Warning - Values clipped in setting A2B LUT!
*** Try switching to XYZ PCS ***
Done A to B table creation
Setting up B to A table lookup
Creating B to A tables
Rev cache RAM = 750 Mbytes
There is 1 rev cache instance with 750 Mbytes limit
There are 2 rev cache instances with 375 Mbytes limit
100%
Done B to A tables
There is 1 rev cache instance with 750 Mbytes limit
profile check complete, peak err = 1.173629, avg err = 0.312902, RMS = 0.355569--

What's exactly the problem?