[argyllcms] Re: Cannot import OEM data for Spyder5

  • From: Jared Breland <list-argyll@xxxxxxxxxxx>
  • To: argyllcms@xxxxxxxxxxxxx, Graeme Gill <graeme@xxxxxxxxxxxxx>
  • Date: Tue, 5 Jan 2021 12:10:21 -0600

awesome, I think that worked:

$ *LD_LIBRARY_PATH=$LD_LIBRARY_PATH:~/oeminst_v213beta ~/oeminst_v213beta/oeminst -v Spyder5Pro_5.5_Setup.exe*
Loading file 'Spyder5Pro_5.5_Setup.exe'..done
'Spyder5Pro_5.5_Setup.exe' seems to be a VISE archive
Input file 'Spyder5Pro_5.5_Setup.exe' is a VISE archive file base 0x10008
Failed to locate file 'CVSpyder.dll' in VISE archive
Input file 'Spyder5Pro_5.5_Setup.exe' is a VISE archive file base 0x10008
Located driver entry 'dccmtr.dll' at offset 0x765be
Located driver file 'dccmtr.dll' at offset 0xa84ebb
Located and decompressed file 'dccmtr.dll' from VISE archive
Returning 'dccmtr.dll' length 54272 from 'Spyder5Pro_5.5_Setup.exe'
Failed to locate Spyder 2 firmware in 'dccmtr.dll'
*Returning 'spyd4cal.bin' length 2296 from 'dccmtr.dll'**
**Wrote '~/.local/share/ArgyllCMS/spyd4cal.bin' 2296 bytes*

Thanks a bunch!  Now to figure out the rest of this whole process. :-)

Jared Breland
jbreland@xxxxxxxxxxx
https://www.legroom.net/

On 1/5/21 2:22 AM, Graeme Gill wrote:

Jared wrote:
If you have a fix, sounds like that'd be easier and
better than hunting down an older version.
Assuming you are using a 64 bit x86 type Linux system you can try this:
<https://www.argyllcms.com/oeminst_v213beta.tgz>

Cheers,
        Graeme Gill.