Along with checking that filter as suggested by Eric, also check to see if the secondary voltages off of the flyback are close to be right on.... Bill ----- Original Message ----- From: "Eric Manuel" <tvman@xxxxxxxxxxxxxxx> To: <techassist@xxxxxxxxxxxxx> Sent: Monday, October 15, 2001 12:45 PM Subject: [TechAssist] Re: sharp ca29t729 tv. horizontal out gets too hot, all measurements seem okay > > Hi Wilf look for a small electro cap near the horizontal driver > transformer maybe 1 mfd or so change it..Eric > > "W. Blakey" wrote: > > > > I have a Sharp tv that I have replaced the HOT (shorted E-C) and the new one gets rather warm also. The B+ is about 125 (I think or 135v), I believe the timing on the collector pulse is 10us or slightly less(reading with Sencore SC60scope) and there is no noise on the hor signal from the driver. I do not have a schematic and am not sure where else to look. > > Wilf Blakey/Blakey TV,Kirkland Lake,Ont > > wblakey@xxxxxxxxxxxxxxxx > > > > Help make your TechAssist online repair tips > > database better! Submit your fixes here: > > http://www.circuitwork.com/techassist/tip/#tips > > To unsubscribe write to: > > techassist-request@xxxxxxxxxxxxx > > with unsubscribe in the subject line. > Help make your TechAssist online repair tips > database better! Submit your fixes here: > http://www.circuitwork.com/techassist/tip/#tips > To unsubscribe write to: > techassist-request@xxxxxxxxxxxxx > with unsubscribe in the subject line. Help make your TechAssist online repair tips database better! Submit your fixes here: http://www.circuitwork.com/techassist/tip/#tips To unsubscribe write to: techassist-request@xxxxxxxxxxxxx with unsubscribe in the subject line.