Always,always ESR those blue caps in these Zeniths..Causes a multitude of strange symptoms. The other day I had a Zenith with 14 caps bad. I just kept ESR'ing and replacing,as the picture got better and better.My Dick-Smith ESR meter is a must.It would be near impossible to zip from one cap to the other without it. If I was running from a burning building the Dick Smith would be under my arm! (Wife under the other!) Jeff Dougherty wrote: > > Initial problem was blown fuse, shorted ICX3431(STR53041) and shorted > Q3431(121-1264-01) > Also, C3432 high ESR, CX3003 decr value. > Now I have a red horizontal band, top of screen about 2" high. > Any help on this one? > Thanks. > > Jeff > > mailto:Jeff@xxxxxxxxxxxxxxxxxx www.9-11-2001tragedy.com > Help those affected by the NY/PA tragedy: > The Red Cross needs is mobilizing a national blood drive and needs your > help. Please call 800-GIVE LIFE, to find out where in your area you can > donate blood. > FAX 1-413-280-0677 > Intrepid Video & Electronics > Harrisburg, PA 17111 > 717-909-8844 > www.intrepid-video.com www.tech-repair.net www.thetoolcaddy.com > > Help make your TechAssist online repair tips > database better! Submit your fixes here: > http://www.circuitwork.com/techassist/tip/#tips > To unsubscribe write to: > techassist-request@xxxxxxxxxxxxx > with unsubscribe in the subject line. Help make your TechAssist online repair tips database better! Submit your fixes here: http://www.circuitwork.com/techassist/tip/#tips To unsubscribe write to: techassist-request@xxxxxxxxxxxxx with unsubscribe in the subject line.