This Sanyo DS27630 came in with a shorted horz. output and R608 and R610 burned and open. When all parts replaced unit played for about 1 hour then shorted the horz. output again and blew the fuse this time. I replaced it again and checked again for and cold solder joints and measured the base of the horz. output (D1555) and it was (-0.03vdc) and after about 10 minutes it was starting to get hot to the touch. I do not have a schematic so I am shooting in the dark. I also replaced the 1 uf 160 cap off of the horz. driver transformer. Any help would really br great. Shaun Advanced Electronics Fort Morgan, CO 80701 (970)867-3124 ssroark@xxxxxxxx ------------------------------------------ To REMOVE your email address, click here: http://www.tech-assist.org/unsubb.html ------------------------------------------ ***NEW*** Tips Added Instantly!!!*** Submit Repair Tips here: http://www.tech-assist.org/secure/tip/