I have fixed a couple of DS31520's--may be similar. Check/replace Q604/2SC3807 and Q605/2SA608N or 2SA1015. HTH, Ken Smith Gulf Technical Services 3034 Gulf Breeze Parkway Gulf Breeze, FL 32563 850-934-8324 (Voice) 850-932-0819 (Fax) On Thu, 5 Aug 2004 15:08:25 -0400 "Tel-Tek Electronics" <teltek3@xxxxxxxxxxxx> writes: > Have one here that was put out during a lightning storm. > No fuses blown. No Relay click. > Any common problems on these after lightning. The set was off, but > plugged in. > > I have 150Volts on Main filter. > I realize I'm not giving you much to go on....;-) > > Anyone have one of these after a thunderstorm, and was able to fix > it? > > TIA. > > -Ed- > > Tel-Tek Electronics > teltek3@xxxxxxxxxxxx > Ontario-Canada > > > > ------------------------------------------------------------------------- ---- > Lost Password: > http://www.tech-assist.org and select "Login Problems?". > Email Archives: > //www.freelists.org/archives/techassist/ > > ----------------------------------------------------------------------------- Lost Password: http://www.tech-assist.org and select "Login Problems?". Email Archives: //www.freelists.org/archives/techassist/