Came in with the HOT shorted. After replacing it, the set ran but intermittantly seemed to pull in from the sides. Turned out to be a cap in the H. drive ckt, location# 2455 (47mfd@25V) was open. Replaced cap, cured. I found archived email relating to this , and said also check resistor #3411 for open. Ours was OK. Phil Bader -- Philip Bader Jan Phyl TV Inc. (estab. 1976) 3420 Recker Hwy. Winter Haven, Fl. 33880 Fax (863) 299-8821 email: tjanphyl@xxxxxxxxxxxxxxx ----------------------------------------------------------------------------- Lost Password: http://www.tech-assist.org and select "Login Problems?". Email Archives: //www.freelists.org/archives/techassist/