change the vert ic and caps also change caps in the power supply 47 micro 16 volts c914,c915 good luck Pete Perdomo Tv Inc Since 1972 Miami.Fl ----- Original Message ----- From: "Paul" <dntwntv@xxxxxxxxxxxxx> To: <techassist@xxxxxxxxxxxxx> Sent: Wednesday, June 15, 2005 4:08 PM Subject: [TechAssist] Mitsubishi VS-50VF2 V-12 Ch. > There is no light from any of the pic tubes. There is filament and the > vertical circuit is ok. I can not check the High Voltage due to a faulty > HV probe. I checked for an arc from the HV and it is very weak. The Wave > forms and voltages at the Horiz output and High voltag outputs are > normal. Is it possible to have a bad Flyback with everything else normal? > Don't remember having anything like this before. I have been checking the > spot killer and RGB outs for the problem and have come up empty handed. > Paul > > Paul ,B > Central TV&Video > 911W Grand Ave > Grover Beach Ca. > (805)481-8084 > > ----------------------------------------------------------------------------- > This Email List is Public. Remove: http://www.tech-assist.org/remove.htm > Lost Password: http://www.tech-assist.org and select "Login Problems?". > Appliance Repair List: > http://www.tech-assist.org/secure/tip/chatjoin.htm#app > Email Archives: //www.freelists.org/archives/techassist/ > > > -- > No virus found in this incoming message. > Checked by AVG Anti-Virus. > Version: 7.0.323 / Virus Database: 267.7.5/18 - Release Date: 6/15/2005 > > ----------------------------------------------------------------------------- This Email List is Public. Remove: http://www.tech-assist.org/remove.htm Lost Password: http://www.tech-assist.org and select "Login Problems?". Appliance Repair List: http://www.tech-assist.org/secure/tip/chatjoin.htm#app Email Archives: //www.freelists.org/archives/techassist/