Dear All: Sometime ago, I have proposed one question about nonlinear in power ground noise of clock driver. We have found that there is no nonlinear in the power ground noise and the decoupling circuit. We made some mistake in measurement: 1.The probe shoulde not be on one cap. The cap should be soldered off. Otherwise, the power ground noise is "colored" by the caps. 2.When one oscilloscope is used to measure power ground noise. The system impedance should be turned to 50ohm in order to prevent oscillation in the transmission line. Somebody asked me which kind of mistake we have made. They are above:) Thanks to Istvan Novak and Larry Smith for their help. Best Regards Zhangkun 2003.12.9 ------------------------------------------------------------------ To unsubscribe from si-list: si-list-request@xxxxxxxxxxxxx with 'unsubscribe' in the Subject field or to administer your membership from a web page, go to: //www.freelists.org/webpage/si-list For help: si-list-request@xxxxxxxxxxxxx with 'help' in the Subject field List technical documents are available at: http://www.si-list.org List archives are viewable at: //www.freelists.org/archives/si-list or at our remote archives: http://groups.yahoo.com/group/si-list/messages Old (prior to June 6, 2001) list archives are viewable at: http://www.qsl.net/wb6tpu