Peter, There is a utility called "spc2spc" that converts the SPECCTRAQuest simulator netlist into a standard flattened SPICE netlist. With the 14.0 and later releases, the utility has a "-welement" option that causes it to output transmission lines using the W element model. Remember that you can't extract a coupled line into SigXp. If you're building the coupled net model from scratch in SigXp, fine. If you want to analyze a coupled net from an actual layout, you'll have to run the analysis in SPECCTRAQuest floorplanner first, then find and convert the SPECCTRAQuest netlist used to perform that simulation. In either case, you set yourself into the directory where the SQ simulator netlist is, and run spc2spc. The arguments are different between 13.6 and 14.0, but "spc2spc -h" should give you the option list. One last point - for spc2spc to run, a SQ simulator netlist must exist. That means that SQ/SigXp has already run a simulation, or tried to. If you never try to analyze anything in SQ/SigXp, it won't bother to build a netlist. Hope that helps, Todd. Todd Westerhoff SI Engineer Hammerhead Networks 5 Federal Street Billerica, MA 01821 twester@xxxxxxxxxxx ph: 978-671-5084 -----Original Message----- From: si-list-bounce@xxxxxxxxxxxxx [mailto:si-list-bounce@xxxxxxxxxxxxx]On Behalf Of Peter LaFlamme Sent: Friday, July 13, 2001 9:05 AM To: si list Subject: [SI-LIST] extraction of RLGC matrices from Sigexplorer Hi SI List, I am currently trying to do some HSPICE simulations on broadside coupled lines. I do not have access to a field solver to create the necessary RLGC information needed for the W-Element. We have a spectraquest license and I had heard that I could export a net from either sigexplorer to HSPICE compatible format or from a board layout in spectraquest. Is there anyone who has experience doing this. I would have contacted cadence, but I believe that there is a quicker turnaround time on the SI List, that is if someone knows the answer. Also I thought others may be in a similar situation and would find this information useful. Thanks, Peter -- Peter LaFlamme Applied Micro Circuits Corp. Staff System Applications Engineer 200 Minuteman Rd, 3rd Floor Andover, MA 01810 978-247-8470 phone 978-623-0055 Fax ------------------------------------------------------------------ To unsubscribe from si-list: si-list-request@xxxxxxxxxxxxx with 'unsubscribe' in the Subject field For help: si-list-request@xxxxxxxxxxxxx with 'help' in the Subject field List archives are viewable at: //www.freelists.org/archives/si-list or at our remote archives: http://groups.yahoo.com/group/si-list/messages Old (prior to June 6, 2001) list archives are viewable at: http://www.qsl.net/wb6tpu ------------------------------------------------------------------ To unsubscribe from si-list: si-list-request@xxxxxxxxxxxxx with 'unsubscribe' in the Subject field For help: si-list-request@xxxxxxxxxxxxx with 'help' in the Subject field List archives are viewable at: //www.freelists.org/archives/si-list or at our remote archives: http://groups.yahoo.com/group/si-list/messages Old (prior to June 6, 2001) list archives are viewable at: http://www.qsl.net/wb6tpu