[SI-LIST] Coaxial TEM Cutoff Frequency

  • From: "Moeller, Merrick" <mmoeller@xxxxxxxxxxxxxxx>
  • To: "Si-List (E-mail)" <si-list@xxxxxxxxxxxxx>
  • Date: Thu, 11 Dec 2003 13:57:52 -0600

Experts,
        I have been searching for a hand calculation of cutoff frequency
for a coaxial contact. I have been able to find many for coaxial cable. However,
I do not know the assumptions that are being made to derive these equations.
Cutoff Frequency = 7.5/SQRT(er)(D+d)
or
Cutoff Frequency= ((2*c)/(PI*sqrt(er)))*1/(D+d)

D = Sheild inner diameter
d = Conductor outer diameter

Any insight?

Thanks,
Merrick



------------------------------------------------------------------