[THIN] Re: XenApp disconnects

  • From: "Joe Shonk" <joe.shonk@xxxxxxxxx>
  • To: <thin@xxxxxxxxxxxxx>
  • Date: Tue, 27 Jul 2010 15:47:45 -0700

Like Jeremy mentioned before. Just use the Terminal Server time out values
in the GPO.   This value works with XA 4.5/5 for ICA traffic with no
additional configuration required.

 

Joe

 

From: thin-bounce@xxxxxxxxxxxxx [mailto:thin-bounce@xxxxxxxxxxxxx] On Behalf
Of Andrew Wood
Sent: Tuesday, July 27, 2010 10:25 AM
To: thin@xxxxxxxxxxxxx
Subject: [THIN] Re: XenApp disconnects

 

HKLM\SYSTEM\CurrentControlSet\Control\Terminal
Server\Winstations\ICA-TCP\MaxIdleTime

HKLM\SYSTEM\CurrentControlSet\Control\Terminal
Server\Winstations\ICA-TCP\fInheritMaxIdleTime

HKLM\SYSTEM\CurrentControlSet\Control\Terminal
Server\Winstations\ICA-TCP\fInheritResetBroken

HKLM\SYSTEM\CurrentControlSet\Control\Terminal
Server\Winstations\ICA-TCP\fResetBroken

 

Are the values you'll need to change - you could just script it as part of
the Ctx install.

 

From: thin-bounce@xxxxxxxxxxxxx [mailto:thin-bounce@xxxxxxxxxxxxx] On Behalf
Of Hamilton, Ronnie
Sent: 27 July 2010 16:10
To: thin@xxxxxxxxxxxxx
Subject: [THIN] XenApp disconnects

 

Hi,

 

Is it possible to configure the ICA-tcp connection in Terminal services
configuration in windows 2003 with XenApp 4.5.

 

I have been manually doing this but can this be done using Windows server
GPO a citrix policy or is there a special template that can be imported.

 

thanks

Ronnie

 

 

 

 

 

Visit our website : www.ltai.ie 

__________________________________________

Lufthansa Technik Airmotive Ireland Limited. Registered in Ireland. Reg. No.
45999. Registered Office: Naas Road, Rathcoole, Co.Dublin.

Lufthansa Technik Airmotive Ireland Leasing Limited. Registered in Ireland.
Reg. No. 140891. Registered Office: Naas Road, Rathcoole, Co.Dublin.

__________________________________________

The information in this email and in any attachments is confidential and may
be privileged. If you are not the intended recipient, please destroy this
message, delete any copies held on your systems and notify the sender by
return email. You should not read, retain, copy, disseminate, distribute,
disclose or use this email or its contents in any way. Any such action is
strictly prohibited. Thank you.

 

 

Other related posts: