[THIN] Web Interface Event Log Shows an Error of Type IMA with an Error ID of 0x80000001 Reported by the XML Service

  • From: "Carl Stalhood" <cstalhood@xxxxxxxxx>
  • To: thin@xxxxxxxxxxxxx
  • Date: Mon, 5 Jan 2009 13:03:13 -0600

I think somebody reported this issue last week. A new KB article was posted.

This problem occurs in a mixed farm environment of Presentation Server 4.5
and Presentation Server 4.0, where the XML broker is the Presentation Server
4.5 server. In Presentation Server 4.5, ccticket can talk to IMA using RPC
or XML. In Presentation Server 4.0, this communication is XML only. The
LaunchReference string fails because this API does not exist in Presentation
Server 4.0. When the RPC request fails, the Presentation Server 4.5 ccticket
falls back to the XML request, which is by design. The Web Interface
generates an event log error as a result of the fallback from RPC to XML.

http://support.citrix.com/article/CTX118905