I have had some problems with the MK12 mechanism (made in 2003 and 2004) with tape spillage at eject. It was the slider plate on the bottom of the mechanism. Problems would occur when set was warm and cassette was ejected, apparently the plastic would warp. It's not hard to change. It does not sound like mode switch, that ussually caused frontload/eject problems. John. John Mielke Main TV Longmont,Co 80501 303 776 6955 303 776 0792 fax maintv2004@xxxxxxxxxxx www.longmontmaintv.com ----- Original Message ----- From: "Phil Bader" <tjanphyl@xxxxxxxxxxxxxxx> To: <techassist@xxxxxxxxxxxxx> Sent: Monday, March 14, 2005 11:33 AM Subject: [TechAssist] new emerson,funai,sylvania, TVCRs: Tape on wrong side of pinch roller,causining upon eject > We've seen a lot of this symptom for no aparent cause. Any one know the > little fix for this aparent repeat failure? > Phil Bader > > -- > > Philip Bader > Jan Phyl TV Inc. (estab. 1976) > 3420 Recker Hwy. Winter Haven, Fl. 33880 > Fax (863) 299-8821 > email: tjanphyl@xxxxxxxxxxxxxxx > > -------------------------------------------------------------------------- --- > This Email List is Public. Remove: http://www.tech-assist.org/remove.htm > Lost Password: http://www.tech-assist.org and select "Login Problems?". > Email Archives: //www.freelists.org/archives/techassist/ > ----------------------------------------------------------------------------- This Email List is Public. Remove: http://www.tech-assist.org/remove.htm Lost Password: http://www.tech-assist.org and select "Login Problems?". Email Archives: //www.freelists.org/archives/techassist/