[TechAssist] Re: Zenith A17196-12 splitters resistance

  • From: Philip Bader <tjanphyl@xxxxxxxxxxxxxxx>
  • To: techassist@xxxxxxxxxxxxx
  • Date: Fri, 08 Aug 2003 18:21:30 -0400

The Zenith tech assist said to unplug the connector F4 on sweep module
and measure the two grey wires that go to the HV block. They should
measure between 46-52K ohms if good..
Phil Bader

ERNtv@xxxxxxx wrote:
> 
> Its always been my understanding that anything above 52K is considered bad
> 
> Scott
> Ernies Tv
> Loveland , Co
> 
> *****************************************************************************
> Classifieds! Buy or Sell!
> http://sell.tech-assist.org
> The Tech Address Book:
> http://www.tech-assist.org/secure/tip/contact.htm
> Add a Repair Tip Here, or Change/Remove your Email Address:
> http://www.tech-assist.org/secure/tip/main.htm
> Lost Password:
> http://www.tech-assist.org  and select "Lost your Login Info?".
> Email Archives:
> //www.freelists.org/archives/techassist/

-- 
Philip Bader
Jan Phyl TV Inc. (estab. 1976)
3420 Recker Hwy. Winter Haven, Fl. 33880
Fax (863) 299-8821      
email: tjanphyl@xxxxxxxxxxxxxxx

*****************************************************************************