Picture pulled up at bottom, stretch at top, severe. Replaced caps C342 (1mfd@50V) and C305 (2.2mfd@50V), went over the entire circuit. Cleaned the ckt board (storm damage aparently caused a roof leak and water dripped onto the set). Chemically cleaned the CBA and dried thoroughly. Water unrelated to the vertical issue. Phil Bader -- Philip Bader Jan Phyl TV Inc. (estab. 1976) 3420 Recker Hwy. Winter Haven, Fl. 33880 Fax (863) 299-8821 email: tjanphyl@xxxxxxxxxxxxxxx ----------------------------------------------------------------------------- Lost Password: http://www.tech-assist.org and select "Login Problems?". Email Archives: //www.freelists.org/archives/techassist/