This guy used a power generator for his house during the hurricanes.
Dead, fuses OK. First, noticed HOT collector had short to gnd. Lifted 
HOT, short still on the +135V line. Traced back (no easy task) to the 
main SMPS source. SMPS T603 pin17, to rectifiers D611 and D624 (both 
OK). Then there's a zener to ground in this output, D614 (EZ0150AV1 / 
8-719-057-52). I think it's 150V a clamp for when the source climbs too 
high. Shorted. Lifted it, all shorts gone. Any ideas on this? I can 
either just lift it and try powering up, or sub a crude  substitute as 
test (say two 75v in series=150V). Anyone seen this diode be bad, and 
anything else usually goes?
Phil Bader

-- 

Philip Bader
Jan Phyl TV Inc. (estab. 1976)
3420 Recker Hwy. Winter Haven, Fl. 33880
Fax (863) 299-8821
email: tjanphyl@xxxxxxxxxxxxxxx

-----------------------------------------------------------------------------