Mike
Look at cap c4401 If it is bulging out on the sides replace it
its a 200149 cap also replace the diode cr4401 (164589) and just for good 
measure
replace 200148 it is the pincushion transistor

Good luck
Tom


mhuppert4 wrote:

> Has anyone  else worked on pincushion/width problems on a Proscan PS3112? I' 
> ve changed everything in the circuit, yet neither the width or e/w pots do 
> anything to the picture. All signals are good except the waveform going into 
> u4801 pin 3. Any clues would be great!
>
> Mike