[TechAssist] Re: Panasonic AG-1970P

  • From: "Jeff Dougherty" <jeff@xxxxxxxxxxxxxxxxxx>
  • To: <techassist@xxxxxxxxxxxxx>
  • Date: Sat, 26 Jan 2002 10:08:31 -0500

Bill,
First check the voltage to chassis ground. You should get 9-12vdc. If
low, check the voltage out of the load motor IC, if missing there,
replace IC.


Jeff
Order your tech repair CD today. Free tip updates for one
year.($49.00)over 50,000 repair tips
www.tech-repair.net
Also visit www.intrepid-video.com www.thetoolcaddy.com
www.9-11-2001tragedy.com

-----Original Message-----
From: techassist-bounce@xxxxxxxxxxxxx
[mailto:techassist-bounce@xxxxxxxxxxxxx] On Behalf Of Bill Grabowski
Sent: Thursday, January 24, 2002 9:56 PM
To: Techassist
Subject: [TechAssist] Panasonic AG-1970P


    Has anyone had a Panasonic AG-1970P with no loading what so
ever.....the
loading platform is moving smooth when test jig inserted but no motor
movment.
And there's only 2.5 volts across the loading motor. Shouldn't I have
more
voltage across the motor.Any help would be appreciated........  
Thanks!!


Bill Grabowski
Triangle Appliance
Kenosha,WI
------------------------------------------
Make your TechAssist database better!  
Submit Repair Tips here: http://www.tech-assist.org/secure/tip/
------------------------------------------
To UNSUBSCRIBE your email address, click here:
mailto:techassist-request@xxxxxxxxxxxxx?subject=unsubscribe
Or send a BLANK email with unsubscribe in the
SUBJECT field to the address above.

------------------------------------------
Make your TechAssist database better!  
Submit Repair Tips here: http://www.tech-assist.org/secure/tip/
------------------------------------------
To UNSUBSCRIBE your email address, click here:
mailto:techassist-request@xxxxxxxxxxxxx?subject=unsubscribe
Or send a BLANK email with unsubscribe in the
SUBJECT field to the address above.

Other related posts: