[TechAssist] Re: PTK195, B+ high at about 162 volts

  • From: "majorthom@xxxxxxxxxxxxx" <majorthom@xxxxxxxxxxxxx>
  • To: techassist@xxxxxxxxxxxxx
  • Date: Sat, 11 Jun 2005 14:17:22 -0700 (PDT)

How about the light bulb trick? I've put it in place of pulled main fuse OR @ 
the B+ feed to fly.As a mattter 0of fact load the 160VDC w/a light bulb, or 2 
bulbs in series while you tblsht
Pete
 

Jim Myers <jr.myers@xxxxxxxxxxx> wrote:
HOT was shorted, sub HOT allowed chassis to start up but with a loud 
snap and shorted the sub HOT. Now with a new FBT it shuts down due to 
the high B+ but does not short the sub HOT. Intention is to not install 
the new OEM HOT until the high B+ is fixed.
Does anyone have a tip?