[TechAssist] PTK 169bu no apparant raster!

  • From: Hermantvr@xxxxxxxxxxxxx
  • To: techassist@xxxxxxxxxxxxx
  • Date: Sat, 16 Nov 2002 09:51:57 EST

Asked about this one before, still no fix and have not been able to find 
problem. NO raster...if I run screen control up there is a slight raster with 
retrace lines....this means the sweep circuits are working. TTP 98-004 says 
to troubleshoot the scan loss circtuit for this symptom. The bulliten says 
that pin 8 of U7005 should be VCC for the scan loss circuit, however there is 
nothing connected to pin 8 of that IC. If I use RCA's wonderful schematics I 
have to run through pages and pages of service data and still cannot find pin 
8 of U7005. I can physically find it on the IC and there is no trace going to 
pin 8 the schaematic shows only the comparator pins on U7005 but it is hard 
if not impossible to troubleshoot this circuit with out more info. any help 
will be .....well.... help!!!    thanks!

Tommy Herman
Herman TV
250 School Ave SW
Taylorsville,  N.C.  28681
828-632-58322 Voice
828-632-3880   Fax
hermantvr@xxxxxxxxxxxxx
------------------------------------------